Strobe Division 2 Hazardous Location


Strobe Division 2 Hazardous Location
Quantity in Basket: None
Code: 490STdiv2
Price: $208.00
Shipping Weight: 1.00 pounds
Select Lens Color:
Red 
Amber 
Green 
Blue 
Clear 
Select Voltage:
12-80 Volt DC 
120 Volt AC 
 
Spare Flash Tube Lamp 5001 Add $18.00




View Product Files:

 

The model 490S-1280T and 490S-120T strobe lights are UL listed for use in Class I & II, Division 2 hazardous locations. Division 2 locations are defined by the NFPA as shown below. These units have a Lexan® lens and base and are suitable for use in NEMA 4X outdoor locations. They may be operated in any position and feature a 1/2” pipe mount hub. This model is an economical strobe for the listed hazardous locations. The flash intensity of this model is suited to indoor applications, or where the strobe flash would have limited competition for visibility from bright ambient light or light outdoors (e.g. direct or indirect sun light). Compare Joule flash energy and or candela effective (ECP) rating when comparing different models for your application.

 

Features:

  • Class I, Div. 2 Groups A, B, C, & D Class II, Div 2 Groups F & G Class III
  • Lens has hermetic O-ring seal Available in amber, blue, clear, green, and red
  • 10 year warranty on power supply
  • UL listed NEMA 4X
  • Model Description/ Voltage: 490S–1280T Hazardous location strobe 12 – 80VDC 490S–120T Hazardous location strobe 120VAC
  • Specifications:

  • Lamp Type 5001 Xenon strobe lamp Lens Type 470S–L–Color ( please specify lens color above)
  • Flash Rate 60 to 80 flashes per minute Light Output 50 candela eff (2.3 joules per flash).
  •  Voltage and Amperage 12–80VDC draws 0.4A average @ 12VDC draws tapering to 0.05A average @ 80VDC 16–24VAC draws 0.35A average 120VAC draws 0.04A average
  • Temperature Code Class I T2C 230° C Do not install where the operating temperature exceeds the ignition temperature of the hazardous atmosphere.
  • Power Supply Output 2.7 Watts
  • Size and Weight 5” tall x 3” dia., 0.6 lbs ( 127mm x 76mm)
  •  

     NFPA Definitions:

  • Class I, Division 2. A location (1) in which volatile flammable liquids or flammable gases are handled, processed or used, but in which the liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in case of abnormal operation of equipment; or (2) in which ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operation of the ventilating equipment; or (3) that is adjacent to a Class I Division 1 location, and to which ignitable concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive–pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. [See Section 500–4(b) of NFPA 70, National Electrical Code.] Class II, Division 2. A location in which (1) combustible dust will not normally be in suspension in the air in quantities sufficient to produce explosive or ignitable mixtures and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus; or (2) dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and dust accumulations resulting therefrom may be ignitable by abnormal operation or failure of electrical equipment or other apparatus. [See Section 500–5 (b) of NFPA 70, National Electrical Code.]
  •  

    Architect and Engineer Specifications:

  • Hazardous Location visual signaling beacon shall be Tomar model number series 490S-1280T, 490S-120T or approved equal. The beacon shall be UL Listed Class I, Division II, Groups A,B,C, and D; Class II, Division II, Groups F and G; and Class III for use in specified hazardous locations as classified by the National Electric Code. The light source shall be a plug-in field replaceable single-flash xenon strobe lamp. The warning signal must have built-in RFI filters to protect against radio interference and spike voltages. It shall be polarity protected, and have a power supply fully potted in polyurethane. Voltage ranges shall be 12-80VDC or 120 VAC. The warning light shall be rated NEMA 4X and have a screw-on Lexan® lens.



  • Related Item(s)

    Code Name Price  
    878EX-N5 Horn Vibrating Explosion Proof $660.00
    105XBRi LED Status Light Red, Amber, Green, Div 2-105XBRi $325.00
    1002WEP Sounder Electronic Explosion Proof $869.00
    AST-14 Strobe Hazardous Area Rated NEMA 4X $339.95
    5530M Audible Signal High Volume with Tone selection 5530M-N5 $660.00
    RMS-6T-EXP-WP Pull Station Explosion Proof $492.50
    5001 Strobe Lamp replacement for MicroStrobe $18.00
    350WBX Horn Hazardous Location Div 2 $275.00