Store Front Account Search  My Favorites Product List Basket Contents Checkout   NFIB represents the interests of small and independent business owners before federal and state legislative and executive branches of government. As a matter of policy, NFIB does not endorse or promote the products and services of its members. Click to verify BBB accreditation and to see a BBB report.
HACKER SAFE certified sites prevent over 99.9% of hacker crime.
LOG IN/SIGN IN

Basket Contents
Quantity in Basket: none

Recently Visited Items

 
Contact  Us:
Toll Free: 866-925-2768
Ph: 630-749-4144
Fax: 815-485-2510

Email  sales@signalguys.com

Search

Federal Government Contractor
(CCR) CAGE CODE# 1WP09

Andon Lights
Audible Signals
Audible Visual Combination
Backup Alarm
Battery Operated Andon Light
Battery Operated Lights
Bells
Dock Lights
Electronic Sounders
Evacuation Alarms
Explosion Proof / Hazardous
Explosion Proof Pull Station
Fire Alarm Horn
Fire Alarm Horn Strobe
Fire Alarm Strobe
Flashing Lights
Fork Truck Lights
Horns
Industrial Signaling
Intercoms
LED Lights
Lunch Horn Package
Miscellaneous
Municipal Products
Notification
Parts Replacement
Pole Hand Hole Cover
Power Supplies
Pull Station
Radio Based Products(RF)
Rotating Explosion Proof
Rotating Lights
Siren
Sounder Electronic
Speaker Explosion Proof
Speakers
Strobe Explosion Proof
Strobe Lights
Switches
Telephone Alert
Tower Lights
Truck Lights
Visual Signals ( Lights )
Voice Gun Megaphone
Vorne Compatible
Wireless

 
 
Contact  Us:
Toll Free: 866-925-2768
Ph: 630-749-4144
Fax: 815-485-2510
Email: sales@signalguys.com
Federal Government Contractor
(CCR) CAGE CODE #1WP09


Explosion Proof LED Light
 
Explosion Proof LED Light Quantity in Basket: None
Code: 3124XLP
Price: $949.00
Shipping Weight: 13.00 pounds
 
Select LED Light Color: 
Red 
Amber 
Green 
Blue 
White 
Magenta 
Select Voltage Range: 
10-36 Volt DC 
85-265 Volt AC 
Select mounting Type: 
Pendant Mount "XLP" 
Ceiling Mount "XLF" Add $148.00
Wall Mount Bracket "XLW" Add $225.00
Select Factory Set Steady or Flash 1 or Flash 2: 
Steady Burn 
Single Flash 
Double Flash 
 
Optional Cast Dome Guard (BEPG) Add $35.00
 
Quantity:
 

Introducing the Model 3000 family of LED explosion-proof lights (Standard pendant mount unit priced above--select optional features to calculate product pricing). These warning lights are UL listed for Class 1, Division 1, Groups C & D; Class 2, Division 1, Groups E, F & G; Class 1, Division 2, Groups A, B, and Class 3. They are available in six LED colors (Amber, Blue, Green, Magenta, Red, and White).

These explosion-proof LED lights feature a unique thermal management system that utilizes internal cooling fins to draw heat away from the LED’s. This allows for longer lamp life and more consistent light output. All electronics and LED’s are guaranteed against manufacturing defects for a full 5 years.

An internal switch allows for easy selection among steady-burning, single or double flash mode. The steady burning mode addresses the need for a steady Green (“GO” condition) light in applications otherwise utilizing strobe lights for alarm signaling.  The flashing mode versions offer an effective long life light source for alarm signaling. Each light will operate over a wide AC and DC input voltage range. The DC version is designed to operate from 10-36 VDC; the AC version from 85-265 VAC.

The compact 3000 family series are constructed to NEMA 4X standards and are marine-rated for use in salt water environments. Design features include housing made of die cast high strength copper-free aluminum alloy with baked powder epoxy finish, stainless steel hardware, o-ring sealed pre-stressed glass dome with double pitch acme threads for smooth assembly and ease of maintenance.

Features:

·        Super-Bright, high-power LED cluster for superior light output and greater lens fill.

·        Unique Thermal Management System utilizes internal cooling fins to draw heat away from the LED’s. This allows for longer LED life and more consistent light output

·        DIP switch selectable single-flash, double-flash, or steady-burn mode

Order just the mounting style you need – Pendant, Flange (Ceiling), or Wall mount--all mounts have 3/4" hubs.

Specifications :

·         Lamp Type LED

·         Flash Rate 80 Single Flash per minute

·         40 Double Flash per minute

 Voltage and Amperage:

·         167 mA @ 24 VDC for Single Flash -

·         033 mA @ 120 VAC for Single Flash -

·         017 mA @ 240 VAC for Single Flash -

Operating Temperature -40 C to 85 C

Temperature Code T6 - All voltage and temperature ranges

Optional BEPG Lens Guard

 

NFPA Definitions :

Class I, Division 2.

A location (1) in which volatile flammable liquids or flammable gases are handled, processed or used, but in which the liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in case of abnormal operation of equipment; or (2) in which ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operation of the ventilating equipment; or (3) that is adjacent to a Class I Division 1 location, and to which ignitable concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive–pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. [See Section 500–4(b) of NFPA 70, National Electrical Code.]

Class II, Division 2.

A location in which (1) combustible dust will not normally be in suspension in the air in quantities sufficient to produce explosive or ignitable mixtures and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus; or (2) dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and dust accumulations resulting therefrom may be ignitable by abnormal operation or failure of electrical equipment or other apparatus. [See Section 500–5 (b) of NFPA 70, National Electrical Code.]

 


3124 Literature Pg1
3124 Literature Pg1
3124 Literature Pg2
3124 Literature Pg2

We specialize in alarms for industry like: alarm horns, strobes, explosion proof strobes, LED andon lights, stack lights, light towers, speakers, horn strobes, amber beacons, explosion proof speakers, sirens, evacuation sirens, bells, process alarms, beacon lights, intercoms, rotating lights, led lights, flashing lights, beacons, hazardous, level alarms, location strobes, status lamps, buzzers, fire alarm strobes, fire alarm horns, hazard lights, and a great number of items not displayed in our web store. Please contact us for more information.